Wall Profile MPW34

Moores Profiles Other Profiles

Table 1 : Permissible wind pressure (positive) loads in kN/m2 – deflection limit span /f

Sheet Thickness Weight kg/m2 Span Condition Span mm
1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400
0.50mm 4.78 single 2.62 1.98 1.52 1.10 0.82
double 1.95 1.56 1.27 1.06 0.89 0.77
multi 2.39 1.91 1.56 1.30 1.10 0.94 0.82
0.70mm 6.22 single 4.03 3.05 2.14 1.54 1.15 0.88
double 3.24 2.59 2.11 1.76 1.48 1.27 1.10 0.96 0.80
multi 3.98 3.18 2.60 2.16 1.83 1.57 1.25 0.99 0.80
0.90mm 8.42 single 6.34 4.64 3.21 2.32 1.72 1.32 1.03 0.82
double 5.25 4.16 3.38 2.80 2.36 2.01 1.74 1.43 1.16 0.95 0.79
multi 6.47 5.13 4.17 3.46 2.92 2.30 1.80 1.43 1.16 0.95 0.79

 

Table 2 : Permissible wind suction (negative) loads in kN/m2 – deflection limit span /150

Sheet Thickness Weight kg/m2 Span Condition Span mm
1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400
0.50mm 4.78 single 2.25 1.91 1.49 1.20 0.98 0.75
double 2.00 1.60 1.30 1.09 0.92 0.79
multi 2.45 1.96 1.60 1.34 1.13 0.97 0.84
0.70mm 6.22 single 4.17 3.15 2.47 1.83 1.36 1.04 0.81
double 3.18 2.53 2.06 1.72 1.45 1.24 1.07 0.94 0.80
multi 3.90 3.11 2.54 2.11 1.79 1.53 1.25 0.99 0.80
0.90mm 8.42 single 6.33 4.79 3.52 2.54 1.89 1.44 1.3 0.90
double 5.26 4.16 3.38 2.80 2.36 2.02 1.74 1.43 1.6 0.95 0.79
multi 6.48 5.14 4.18 3.47 2.92 2.30 1.80 1.43 1.16 0.95 0.79

This MPW34 profile can be fixed horizontally, vertically or even diagonally. Laying the profile horizontally also permits the inclusion of horizontally mitred corners or curved profile corners. A profile thickness of 0.70mm should be used for these applications.