Wall Profile MPW32

Moores Profiles Other Profiles

Table 1 : Permissible wind pressure (positive) loads in kN/m2 – deflection limit span /150

Sheet Thickness Weight kg/m2 Span Condition Span mm
1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200
0.50mm 4.78 single 3.40 2.46 1.86 1.45 1.07 0.80
double 2.03 1.56 1.24 1.01 0.84
multi 2.50 1.93 1.53 1.25 1.03 0.87 0.75
0.70mm 6.22 single 4.96 3.59 2.71 1.98 1.42 1.06 0.81
double 3.30 2.53 2.00 1.63 1.35 1.14 0.97 0.84
multi 4.06 3.12 2.47 2.01 1.67 1.41 1.20 1.04 0.84
0.90mm 8.42 single 7.51 5.43 3.92 2.72 1.96 1.46 1.11 0.87
double 5.07 3.85 3.03 2.44 2.01 1.67 1.40 1.19 1.02 0.88 0.77
multi 6.29 4.78 3.76 3.04 2.50 2.09 1.75 1.45 1.16 0.94 0.77

 

Table 2 : Permissible wind suction (negative) loads in kN/m2 – deflection limit span /150

Sheet Thickness Weight kg/m2 Span Condition Span mm
1200 1400 1600 1800 2000 2000 2400 2600 2800 3000 3200
0.50mm 4.78 single 2.65 1.92 1.45 1.13 0.91 0.75
double 2.34 1.82 1.46 1.19 1.00 0.84
multi 2.85 2.22 1.78 1.46 1.22 1.04 0.89 0.77
0.70mm 6.22 single 4.21 3.04 2.30 1.80 1.42 1.06 0.81
double 3.63 2.81 2.24 1.82 1.52 1.28 1.10 0.95 0.83
multi 4.45 3.44 2.75 2.24 1.87 1.58 1.35 1.06 0.84
0.90mm 8.42 single 5.91 4.27 3.23 2.53 1.96 1.46 1.11 0.87
double 5.90 4.53 3.59 2.91 2.41 2.03 1.73 1.45 1.16 0.94 0.77
multi 7.27 5.59 4.43 3.60 2.98 2.43 1.86 1.45 1.16 0.94 0.77

The Wall Profile MPW32 is our most popular wall profile.  This profile can be fixed horizontally, vertically or even diagonally. Laying the profile horizontally also permits the inclusion of horizontally mitred corners or curved profile corners. A profile thickness of 0.70mm should be used for these applications.